Autoclave

Autoclave 01

About

SAG provides the services of Heat Treatment for high performance composite parts manufacturing using the most advanced Autoclave by applying carefully controlled levels of heat and pressure to the parts.
Autoclave used for heat treatment in several Applications:

  • Aerospace industry
  • Rubber and Tyre products Industry
  • Glass Lamination Industry

Synthetic Materials

SAG Autoclave provides heat treating for synthetic materials such as: thermoset plastics, adhesives, paints and powder coats, rubber and many others. Common Applications Include:

  • Annealing – removes stresses and increases material strength
  • Curing – helps materials to cross-link and retain defect-free characteristics·
  • Drying – provides a faster liquid removal from the material·
  • Hardening – increases the strength of the material for better resistance to wear
Autoclave 02
Autoclave 02

Synthetic Materials

SAG Autoclave provides heat treating for synthetic materials such as: thermoset plastics, adhesives, paints and powder coats, rubber and many others. Common Applications Include:

  • Annealing – removes stresses and increases material strength
  • Curing – helps materials to cross-link and retain defect-free characteristics·
  • Drying – provides a faster liquid removal from the material·
  • Hardening – increases the strength of the material for better resistance to wear
Autoclave 03

Materials Testing

  • Preheating
  • Analyzing Characteristics
  • Defect Detection
  • Composite Materials
  • Composite Curing
  • Vacuum Bagging

Technical Specification

Interior Dimensions
Working diameter (excluding floor) (4000 mm)
Working length (front of floor to rear H-slot panel)(14000mm)
Temperature Capability
Maximum interior working temperature(400 °C)
Maximum heating rate (average air)5 °C/min)
Maximum cooling rate (average air)(5 °C/min)
Temperature uniformity at steady state(+/- 2 °C)
External shell temperature at maximum temperature< (50 °C)
Pressure Capability
Maximum normal working pressure(15 bar)
Maximum vessel design pressure (MAWP)( 35.5 bar)
Maximum pressurization rate (average)(0.5 bar/min)
Maximum depressurization rate (average)(0.5 bar/min)
Vacuum
Vacuum Source Line Quantity24
Resin filter trapYes
Vacuum Probe Line Quantity30
Thermocouples
Thermocouple typeJ or K
Part temperature thermocouples48
Working mediumOptional operation between (air compressed and nitrogen)
Standard RequiredCE and ASME standards